HOME >> Level >> Level Transmitter >> Guided wave Radar

Magnetrol 705 Hygienic GWR


The hygienic Enhanced Eclipse 705 has been designed to provide unsurpassed level measurement performance beyond that of traditionally used technologies, in the most demanding of applications. The Eclipse 705 has both 3A and EHEDG approval for use in applications that require the most stringent levels of cleanliness and they are ideally suited to both CIP and SIP cleaning regimes.

Eclipse supports the FDT/DTM standard and a PACTware™ PC software package allows for additional configuration and trending flexibility.

Two-wire, 24vdc, loop-powered transmitter for level, volume or interface measurement
Dry validation system allows the user to validate calibration externally, without the need to fill and empty the vessel or remove the probe which offers significant validation cost savings and process downtime.

Multiple bending of the probe allows individual profiling to any vessel shape
Reliable and repeatable measurement is possible from the process connection right down to the probe tip allowing measurement from the first to the last drop and virtually eliminating the dead volume that cannot be measured.

Simple loop tuning via PACTware™ allows reliable and repeatable measurement even when vessel obstructions, such as, agitator blades and spray balls are within 6mm of the probe.

Unaffected by changing process conditions such as vapor layers, foaming, surface agitation, bubbling or boiling, high fill and empty rates, varying dielectric and density changes that badly affect other technologies.
[File click here to view file attachment]